7R6V
Human EXOG complexed with dRP-containing DNA
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | APS BEAMLINE 19-ID |
Synchrotron site | APS |
Beamline | 19-ID |
Temperature [K] | 100 |
Detector technology | CCD |
Collection date | 2018-06-01 |
Detector | ADSC QUANTUM 315r |
Wavelength(s) | 1.0 |
Spacegroup name | P 1 |
Unit cell lengths | 73.749, 79.085, 79.635 |
Unit cell angles | 69.05, 65.02, 89.72 |
Refinement procedure
Resolution | 50.000 - 2.160 |
Rwork | 0.200 |
R-free | 0.24000 |
Structure solution method | MOLECULAR REPLACEMENT |
Starting model (for MR) | 5t5c |
RMSD bond length | 0.004 |
RMSD bond angle | 0.679 |
Data reduction software | HKL-2000 |
Data scaling software | HKL-2000 |
Phasing software | PHENIX |
Refinement software | PHENIX (1.17) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 50.000 | 2.500 |
High resolution limit [Å] | 2.160 | 2.160 |
Number of reflections | 79362 | 7224 |
<I/σ(I)> | 1.5 | |
Completeness [%] | 97.0 | |
Redundancy | 1.8 | |
CC(1/2) | 0.750 | 0.500 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, HANGING DROP | 292 | 28% PEG 4K, 0.2 M Ammonium Sulphate, 0.1 M Na Acetate Trihydrate pH 4.6 |