Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

7QQD

Nuclear factor one X - NFIX in P21

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsELETTRA BEAMLINE 11.2C
Synchrotron siteELETTRA
Beamline11.2C
Temperature [K]100
Detector technologyPIXEL
Collection date2020-03-11
DetectorDECTRIS PILATUS 6M
Wavelength(s)1.2705
Spacegroup nameP 1 21 1
Unit cell lengths43.171, 98.358, 61.629
Unit cell angles90.00, 92.70, 90.00
Refinement procedure
Resolution49.180 - 2.700
R-factor0.1979
Rwork0.195
R-free0.24280
Structure solution methodSAD
RMSD bond length0.009
RMSD bond angle1.231
Data reduction softwareXDS
Data scaling softwareXSCALE
Phasing softwareSHELXDE
Refinement softwareREFMAC (5.0)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]49.1802.840
High resolution limit [Å]2.7002.700
Rpim0.0540.559
Number of reflections140291374
<I/σ(I)>13.22
Completeness [%]99.3
Redundancy6.6
CC(1/2)0.9680.817
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1MICROBATCH72770.2 M NaSCN, 0.1 M HEPES pH 7.0, 22% PEG 3350

222624

PDB entries from 2024-07-17

PDB statisticsPDBj update infoContact PDBjnumon