7Q1E
CPAP:TUBULIN:IIH5 ALPHAREP COMPLEX
Experimental procedure
| Experimental method | SINGLE WAVELENGTH |
| Source type | SYNCHROTRON |
| Source details | SOLEIL BEAMLINE PROXIMA 2 |
| Synchrotron site | SOLEIL |
| Beamline | PROXIMA 2 |
| Temperature [K] | 100 |
| Detector technology | PIXEL |
| Collection date | 2020-03-06 |
| Detector | DECTRIS EIGER X 9M |
| Wavelength(s) | 0.980 |
| Spacegroup name | P 21 21 21 |
| Unit cell lengths | 53.590, 68.050, 420.920 |
| Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
| Resolution | 48.840 - 2.700 |
| R-factor | 0.2025 |
| Rwork | 0.200 |
| R-free | 0.25440 |
| Structure solution method | MOLECULAR REPLACEMENT |
| Starting model (for MR) | 6gwd |
| RMSD bond length | 0.009 |
| RMSD bond angle | 1.000 |
| Data reduction software | XDS |
| Data scaling software | XSCALE |
| Phasing software | PHASER |
| Refinement software | BUSTER (2.10.3 (6-FEB-2020)) |
Data quality characteristics
| Overall | Outer shell | |
| Low resolution limit [Å] | 53.600 | 2.800 |
| High resolution limit [Å] | 2.700 | 2.700 |
| Rmeas | 0.212 | 5.390 |
| Number of reflections | 43707 | 4416 |
| <I/σ(I)> | 12.23 | |
| Completeness [%] | 100.0 | 100 |
| Redundancy | 35.6 | 36.1 |
| CC(1/2) | 0.999 | 0.339 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | VAPOR DIFFUSION | 6.8 | 293 | 8% PEG3350, 0.1M MES-K |