Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | DIAMOND BEAMLINE I24 |
Synchrotron site | Diamond |
Beamline | I24 |
Temperature [K] | 100 |
Detector technology | PIXEL |
Collection date | 2021-03-21 |
Detector | DECTRIS PILATUS 6M |
Wavelength(s) | 0.9999 |
Spacegroup name | P 1 21 1 |
Unit cell lengths | 28.810, 153.730, 75.850 |
Unit cell angles | 90.00, 100.33, 90.00 |
Refinement procedure
Resolution | 38.462 - 1.650 |
Rwork | 0.175 |
R-free | 0.19920 |
Structure solution method | MOLECULAR REPLACEMENT |
Starting model (for MR) | 7oao |
RMSD bond length | 0.007 |
RMSD bond angle | 1.337 |
Data reduction software | xia2 |
Data scaling software | xia2 |
Phasing software | PHASER |
Refinement software | REFMAC (5.8.0267) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 39.000 | 1.690 |
High resolution limit [Å] | 1.650 | 1.650 |
Rpim | 0.044 | 0.560 |
Number of reflections | 77705 | 5819 |
<I/σ(I)> | 10 | 1.2 |
Completeness [%] | 100.0 | 100 |
Redundancy | 6.6 | 6 |
CC(1/2) | 1.000 | 0.600 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, SITTING DROP | 293 | 0.2 M Ammonium fluoride and 20 % Peg 3350 |