Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

7M45

DNA Polymerase Lambda, TTP:At Mg2+ Reaction State Ternary Complex, 120 sec

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsAPS BEAMLINE 22-ID
Synchrotron siteAPS
Beamline22-ID
Temperature [K]100
Detector technologyCCD
Collection date2016-05-24
DetectorMARMOSAIC 300 mm CCD
Wavelength(s)1.00
Spacegroup nameP 21 21 21
Unit cell lengths56.018, 62.547, 140.010
Unit cell angles90.00, 90.00, 90.00
Refinement procedure
Resolution24.016 - 1.889
R-factor0.2062
Rwork0.204
R-free0.24210
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)3upq
Data reduction softwareHKL-2000
Data scaling softwareHKL-2000
Phasing softwareHKL-3000
Refinement softwarePHENIX (v1.15.2-3472)
Data quality characteristics
 OverallInner shellOuter shell
Low resolution limit [Å]50.00050.0001.920
High resolution limit [Å]1.8895.1301.890
Rmerge0.0640.0320.545
Number of reflections3989221631763
<I/σ(I)>13.1
Completeness [%]98.998.188.5
Redundancy11.612.24.8
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, SITTING DROP7.527780-95mM BICINE pH 8.3, 0.3M Na-K Tartrate, 18-22.5% PolyPure PEG

226707

PDB entries from 2024-10-30

PDB statisticsPDBj update infoContact PDBjnumon