7LLI
Stimulatory immune receptor protein complex
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | AUSTRALIAN SYNCHROTRON BEAMLINE MX2 |
Synchrotron site | Australian Synchrotron |
Beamline | MX2 |
Temperature [K] | 100 |
Detector technology | PIXEL |
Collection date | 2020-02-27 |
Detector | DECTRIS EIGER X 16M |
Wavelength(s) | 0.95372 |
Spacegroup name | H 3 |
Unit cell lengths | 296.976, 296.976, 122.635 |
Unit cell angles | 90.00, 90.00, 120.00 |
Refinement procedure
Resolution | 88.750 - 3.200 |
R-factor | 0.2528 |
Rwork | 0.244 |
R-free | 0.26290 |
Structure solution method | MOLECULAR REPLACEMENT |
Starting model (for MR) | 4gup 1tvd 4lfh 5d5m |
RMSD bond length | 0.002 |
RMSD bond angle | 0.609 |
Data reduction software | MOSFLM |
Data scaling software | Aimless |
Phasing software | PHENIX |
Refinement software | PHENIX (1.19.1_4122) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 88.750 | 3.280 |
High resolution limit [Å] | 3.200 | 3.200 |
Number of reflections | 66481 | 4465 |
<I/σ(I)> | 5.9 | |
Completeness [%] | 99.9 | 98.6 |
Redundancy | 8.4 | |
CC(1/2) | 0.990 | 0.770 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, SITTING DROP | 7.5 | 293 | 30-40% PEG 400, 0.1/0.2 HEPES pH 7.5, 0.2M MgCl2 |