7LJ5
Human TRAAK K+ channel FHIEG mutant A198E in a K+ bound conductive conformation
Experimental procedure
| Experimental method | SINGLE WAVELENGTH |
| Source type | SYNCHROTRON |
| Source details | ALS BEAMLINE 8.3.1 |
| Synchrotron site | ALS |
| Beamline | 8.3.1 |
| Temperature [K] | 77 |
| Detector technology | PIXEL |
| Collection date | 2019-10-29 |
| Detector | DECTRIS EIGER2 X 16M |
| Wavelength(s) | 1.11583 |
| Spacegroup name | P 1 21 1 |
| Unit cell lengths | 80.160, 136.980, 95.740 |
| Unit cell angles | 90.00, 94.47, 90.00 |
Refinement procedure
| Resolution | 95.450 - 2.260 |
| R-factor | 0.2216 |
| Rwork | 0.220 |
| R-free | 0.25210 |
| Structure solution method | MOLECULAR REPLACEMENT |
| Starting model (for MR) | 4wfe |
| RMSD bond length | 0.007 |
| RMSD bond angle | 1.406 |
| Data reduction software | XDS |
| Data scaling software | XSCALE |
| Phasing software | PHASER |
| Refinement software | REFMAC (5.8.0257) |
Data quality characteristics
| Overall | Outer shell | |
| Low resolution limit [Å] | 95.450 | 2.504 |
| High resolution limit [Å] | 2.260 | 2.260 |
| Rmerge | 2.827 | |
| Rmeas | 2.884 | |
| Rpim | 0.567 | |
| Number of reflections | 57752 | 2875 |
| <I/σ(I)> | 10.2 | 1.508 |
| Completeness [%] | 93.8 | 12 |
| Redundancy | 27.2 | 12.88 |
| CC(1/2) | 0.971 | 0.578 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | VAPOR DIFFUSION, HANGING DROP | 8.8 | 277 | 50mM Tris pH 8.8, 64-200 mM CaCl2, 27-33 vol vol PEG400 |