7LJ5
Human TRAAK K+ channel FHIEG mutant A198E in a K+ bound conductive conformation
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | ALS BEAMLINE 8.3.1 |
Synchrotron site | ALS |
Beamline | 8.3.1 |
Temperature [K] | 77 |
Detector technology | PIXEL |
Collection date | 2019-10-29 |
Detector | DECTRIS EIGER2 X 16M |
Wavelength(s) | 1.11583 |
Spacegroup name | P 1 21 1 |
Unit cell lengths | 80.160, 136.980, 95.740 |
Unit cell angles | 90.00, 94.47, 90.00 |
Refinement procedure
Resolution | 95.450 - 2.260 |
R-factor | 0.2216 |
Rwork | 0.220 |
R-free | 0.25210 |
Structure solution method | MOLECULAR REPLACEMENT |
Starting model (for MR) | 4wfe |
RMSD bond length | 0.007 |
RMSD bond angle | 1.406 |
Data reduction software | XDS |
Data scaling software | XSCALE |
Phasing software | PHASER |
Refinement software | REFMAC (5.8.0257) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 95.450 | 2.504 |
High resolution limit [Å] | 2.260 | 2.260 |
Rmerge | 2.827 | |
Rmeas | 2.884 | |
Rpim | 0.567 | |
Number of reflections | 57752 | 2875 |
<I/σ(I)> | 10.2 | 1.508 |
Completeness [%] | 93.8 | 12 |
Redundancy | 27.2 | 12.88 |
CC(1/2) | 0.971 | 0.578 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, HANGING DROP | 8.8 | 277 | 50mM Tris pH 8.8, 64-200 mM CaCl2, 27-33 vol vol PEG400 |