Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

7KMH

LY-CoV488 neutralizing antibody against SARS-CoV-2

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsAPS BEAMLINE 31-ID
Synchrotron siteAPS
Beamline31-ID
Temperature [K]100
Detector technologyPIXEL
Collection date2020-05-15
DetectorDECTRIS PILATUS3 S 6M
Wavelength(s)0.9793
Spacegroup nameC 2 2 21
Unit cell lengths74.806, 260.590, 94.997
Unit cell angles90.00, 90.00, 90.00
Refinement procedure
Resolution29.390 - 1.720
R-factor0.1963
Rwork0.194
R-free0.24230
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)7kmg
RMSD bond length0.004
RMSD bond angle1.100
Data reduction softwareXDS
Data scaling softwareAimless
Phasing softwarePHASER
Refinement softwareREFMAC (5.8.0103)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]30.0001.820
High resolution limit [Å]1.7201.720
Rmerge0.0510.630
Number of reflections9721214015
<I/σ(I)>13.43.4
Completeness [%]98.898.8
Redundancy1313.4
CC(1/2)0.9990.973
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, SITTING DROP7.72938% PEG 3350, 200 mM L-Proline, 100 mM Hepes pH 7.7

222926

PDB entries from 2024-07-24

PDB statisticsPDBj update infoContact PDBjnumon