Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | APS BEAMLINE 24-ID-C |
Synchrotron site | APS |
Beamline | 24-ID-C |
Temperature [K] | 100 |
Detector technology | PIXEL |
Collection date | 2020-11-24 |
Detector | DECTRIS EIGER X 16M |
Wavelength(s) | 0.9789 |
Spacegroup name | P 21 21 21 |
Unit cell lengths | 80.205, 83.151, 156.083 |
Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
Resolution | 46.410 - 3.300 |
R-factor | 0.2728 |
Rwork | 0.271 |
R-free | 0.30620 |
Structure solution method | MOLECULAR REPLACEMENT |
Starting model (for MR) | 1y12 |
RMSD bond length | 0.012 |
RMSD bond angle | 1.539 |
Data reduction software | HKL-2000 |
Data scaling software | HKL-2000 |
Phasing software | PHASER |
Refinement software | PHENIX ((1.19.2_4158: ???)) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 46.410 | 3.420 |
High resolution limit [Å] | 3.300 | 3.300 |
Rmerge | 0.120 | 1.310 |
Number of reflections | 15808 | 1191 |
<I/σ(I)> | 22.75 | |
Completeness [%] | 97.2 | |
Redundancy | 10.6 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, HANGING DROP | 298 | 0.2M Ammonium acetate, 0.1M HEPES pH 7.5, 25% PEG 3350 |