Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

7EWA

GDP-bound KRAS G12D in complex with TH-Z827

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeLIQUID ANODE
Source detailsBRUKER METALJET
Temperature [K]100
Detector technologyCMOS
Collection date2021-05-02
DetectorBRUKER PHOTON 100
Wavelength(s)1.34138
Spacegroup nameP 1 21 1
Unit cell lengths46.691, 102.793, 56.395
Unit cell angles90.00, 107.10, 90.00
Refinement procedure
Resolution33.700 - 2.250
R-factor0.2076
Rwork0.203
R-free0.25840
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)4epr
Data reduction softwareSAINT
Data scaling softwareSADABS
Phasing softwarePHASER
Refinement softwarePHENIX (1.17.1)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]50.0002.280
High resolution limit [Å]2.2502.250
Rmerge0.0840.398
Number of reflections47529946
<I/σ(I)>12.633.33
Completeness [%]100.0100
Redundancy9.076.72
CC(1/2)1.0000.950
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1EVAPORATION8.52970.2 M sodium acetate, 0.1 M Tris, pH 8.5, 26 % (w/v) PEG 3350

222624

PDB entries from 2024-07-17

PDB statisticsPDBj update infoContact PDBjnumon