7EIK
RD4-BD1 in complex with LT-872-297
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | SSRF BEAMLINE BL17U1 |
Synchrotron site | SSRF |
Beamline | BL17U1 |
Temperature [K] | 100 |
Detector technology | PIXEL |
Collection date | 2018-10-25 |
Detector | DECTRIS PILATUS 6M |
Wavelength(s) | 0.9793 |
Spacegroup name | P 21 21 21 |
Unit cell lengths | 31.820, 47.340, 82.510 |
Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
Resolution | 41.060 - 1.700 |
R-factor | 0.2313 |
Rwork | 0.228 |
R-free | 0.25830 |
Structure solution method | MOLECULAR REPLACEMENT |
Starting model (for MR) | 5uy9 |
Data reduction software | MOSFLM |
Data scaling software | Aimless |
Phasing software | PHASER |
Refinement software | PHENIX (1.18.2_3874) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 41.060 | 1.730 |
High resolution limit [Å] | 1.700 | 1.700 |
Rmerge | 0.113 | 0.956 |
Number of reflections | 10914 | 579 |
<I/σ(I)> | 4.6 | |
Completeness [%] | 77.7 | |
Redundancy | 2.7 | |
CC(1/2) | 0.986 | 0.376 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, SITTING DROP | 295 | 4 M sodium formate |