7CT7
FECH - inhibitor complex 2
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | PAL/PLS BEAMLINE 5C (4A) |
Synchrotron site | PAL/PLS |
Beamline | 5C (4A) |
Temperature [K] | 100 |
Detector technology | PIXEL |
Collection date | 2019-07-26 |
Detector | DECTRIS EIGER X 9M |
Wavelength(s) | 0.979 |
Spacegroup name | P 21 21 21 |
Unit cell lengths | 88.588, 93.785, 108.457 |
Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
Resolution | 30.000 - 2.000 |
Rwork | 0.191 |
R-free | 0.22200 |
Structure solution method | MOLECULAR REPLACEMENT |
Starting model (for MR) | 3w1w |
RMSD bond length | 0.007 |
RMSD bond angle | 0.812 |
Data reduction software | HKL-2000 |
Data scaling software | HKL-2000 |
Phasing software | PHENIX |
Refinement software | PHENIX (1.14-3260) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 30.000 | 2.070 |
High resolution limit [Å] | 2.000 | 2.000 |
Rmerge | 0.057 | 0.772 |
Number of reflections | 61481 | 6057 |
<I/σ(I)> | 16.1 | |
Completeness [%] | 99.4 | |
Redundancy | 5.1 | |
CC(1/2) | 0.999 | 0.919 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, HANGING DROP | 5.6 | 293 | 0.1M PCB buffer pH 5.6, 15% PEG 3350 |