7BXG
MavC-UBE2N-Ub complex
Experimental procedure
| Experimental method | SINGLE WAVELENGTH |
| Source type | SYNCHROTRON |
| Source details | SSRF BEAMLINE BL18U1 |
| Synchrotron site | SSRF |
| Beamline | BL18U1 |
| Temperature [K] | 80 |
| Detector technology | PIXEL |
| Collection date | 2019-10-11 |
| Detector | DECTRIS PILATUS3 S 6M |
| Wavelength(s) | 0.9793 |
| Spacegroup name | P 65 |
| Unit cell lengths | 150.527, 150.527, 58.372 |
| Unit cell angles | 90.00, 90.00, 120.00 |
Refinement procedure
Data quality characteristics
| Overall | Outer shell | |
| Low resolution limit [Å] | 50.000 | 2.750 |
| High resolution limit [Å] | 2.700 | 2.700 |
| Rmerge | 0.112 | 0.541 |
| Number of reflections | 36277 | 1038 |
| <I/σ(I)> | 29 | |
| Completeness [%] | 100.0 | |
| Redundancy | 14.9 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | VAPOR DIFFUSION | 293 | 0.1 M sodium malonate, pH 7.0, 12% PEG3350 |