7AHU
Anti-FX Fab of mim8 in complex with human FXa
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | SLS BEAMLINE X06DA |
Synchrotron site | SLS |
Beamline | X06DA |
Temperature [K] | 100 |
Detector technology | PIXEL |
Collection date | 2018-06-09 |
Detector | DECTRIS PILATUS 2M |
Wavelength(s) | 1.0000 |
Spacegroup name | P 1 21 1 |
Unit cell lengths | 63.130, 105.250, 145.780 |
Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 48.590 | 2.693 |
High resolution limit [Å] | 2.600 | 2.600 |
Rmerge | 0.121 | 1.024 |
Rmeas | 0.135 | 1.138 |
Rpim | 0.059 | 0.493 |
Number of reflections | 58767 | 30703 |
<I/σ(I)> | 12.31 | |
Completeness [%] | 99.9 | 99.97 |
Redundancy | 5.2 | 5.2 |
CC(1/2) | 0.996 | 0.523 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, SITTING DROP | 6.5 | 291 | 0.2 M sodium acetate, 0.1 M sodium cacodylate, pH 6.5, 18 % (w/v) PEG 8000 |