7AEM
Studies Towards a Reversible EGFR C797S Triple Mutant Inhibitor Series
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | SOLEIL BEAMLINE PROXIMA 1 |
Synchrotron site | SOLEIL |
Beamline | PROXIMA 1 |
Temperature [K] | 100 |
Detector technology | PIXEL |
Collection date | 2016-06-03 |
Detector | DECTRIS PILATUS3 S 6M |
Wavelength(s) | 0.9897 |
Spacegroup name | I 2 3 |
Unit cell lengths | 146.430, 146.430, 146.430 |
Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
Resolution | 39.130 - 2.650 |
R-factor | 0.199 |
Rwork | 0.198 |
R-free | 0.22100 |
Structure solution method | MOLECULAR REPLACEMENT |
Starting model (for MR) | in house |
RMSD bond length | 0.010 |
RMSD bond angle | 1.160 |
Data reduction software | xia2 |
Data scaling software | Aimless (0.5.17) |
Phasing software | PHASER |
Refinement software | BUSTER (2.11.7) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 46.310 | 2.720 |
High resolution limit [Å] | 2.650 | 2.650 |
Rmerge | 0.082 | 0.972 |
Number of reflections | 15326 | 15326 |
<I/σ(I)> | 13.6 | 1.3 |
Completeness [%] | 99.8 | 97.6 |
Redundancy | 8.6 | 8.2 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION | 7.5 | 293 | Tris sodium citrate 0.68M |