7XEI
SARS-CoV-2-prototyped-RBD and CB6-092-Fab complex
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | SSRF BEAMLINE BL10U2 |
Synchrotron site | SSRF |
Beamline | BL10U2 |
Temperature [K] | 100 |
Detector technology | PIXEL |
Collection date | 2021-10-17 |
Detector | DECTRIS EIGER X 16M |
Wavelength(s) | 0.979 |
Spacegroup name | P 1 21 1 |
Unit cell lengths | 80.046, 112.197, 101.741 |
Unit cell angles | 90.00, 100.90, 90.00 |
Refinement procedure
Resolution | 49.950 - 2.760 |
R-factor | 0.2176 |
Rwork | 0.215 |
R-free | 0.26290 |
Structure solution method | MOLECULAR REPLACEMENT |
Starting model (for MR) | 7c01 |
Data reduction software | XDS |
Data scaling software | SCALEPACK |
Phasing software | PHASER |
Refinement software | PHENIX (1.17.1_3660) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 74.610 | 2.910 |
High resolution limit [Å] | 2.760 | 2.760 |
Rmerge | 0.074 | 0.422 |
Number of reflections | 41517 | 4309 |
<I/σ(I)> | 11.1 | 2.5 |
Completeness [%] | 91.8 | |
Redundancy | 3.1 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION | 291 | Ammonium nitrate, PEG 3350 |