7XEG
SARS-CoV-2-Beta-RBD and CB6-092-Fab complex
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | SSRF BEAMLINE BL19U1 |
Synchrotron site | SSRF |
Beamline | BL19U1 |
Temperature [K] | 100 |
Detector technology | PIXEL |
Collection date | 2021-09-21 |
Detector | DECTRIS PILATUS3 6M |
Wavelength(s) | 0.979 |
Spacegroup name | P 1 21 1 |
Unit cell lengths | 80.248, 113.236, 102.098 |
Unit cell angles | 90.00, 100.58, 90.00 |
Refinement procedure
Resolution | 39.240 - 2.690 |
R-factor | 0.1977 |
Rwork | 0.195 |
R-free | 0.24760 |
Structure solution method | MOLECULAR REPLACEMENT |
Starting model (for MR) | 7c01 |
RMSD bond length | 0.004 |
RMSD bond angle | 0.840 |
Data reduction software | HKL-2000 |
Data scaling software | SCALEPACK |
Phasing software | PHASER |
Refinement software | PHENIX (1.17.1_3660) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 50.000 | 2.790 |
High resolution limit [Å] | 2.690 | 2.690 |
Rmerge | 0.189 | 0.863 |
Number of reflections | 47674 | 3714 |
<I/σ(I)> | 10 | |
Completeness [%] | 99.5 | |
Redundancy | 6.7 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION | 291 | Tris pH 8.0, PEG 2000 |