7W5R
KRAS G12V and peptide complex
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | PAL/PLS BEAMLINE 7A (6B, 6C1) |
Synchrotron site | PAL/PLS |
Beamline | 7A (6B, 6C1) |
Temperature [K] | 100 |
Detector technology | CCD |
Collection date | 2020-07-10 |
Detector | ADSC QUANTUM 270 |
Wavelength(s) | 0.979 |
Spacegroup name | P 1 |
Unit cell lengths | 40.556, 82.513, 82.573 |
Unit cell angles | 119.99, 90.06, 90.02 |
Refinement procedure
Resolution | 35.760 - 3.870 |
R-factor | 0.2277 |
Rwork | 0.223 |
R-free | 0.31020 |
Structure solution method | MOLECULAR REPLACEMENT |
Starting model (for MR) | 5uqw |
RMSD bond length | 0.005 |
RMSD bond angle | 0.992 |
Data reduction software | HKL-2000 |
Data scaling software | CCP4i |
Refinement software | PHENIX (1.14_3260) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 50.000 | 3.950 |
High resolution limit [Å] | 3.870 | 3.870 |
Rmerge | 0.088 | 0.184 |
Number of reflections | 8581 | 2674 |
<I/σ(I)> | 17.3 | |
Completeness [%] | 99.6 | |
Redundancy | 3.8 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, HANGING DROP | 293.15 | polyethylene glycol 3350, 0.2 M potassium nitrate at pH 6.8 |