7UOA
MAGEA4-MTP1 linear peptide complex
Experimental procedure
| Experimental method | SINGLE WAVELENGTH |
| Source type | SYNCHROTRON |
| Source details | APS BEAMLINE 22-ID |
| Synchrotron site | APS |
| Beamline | 22-ID |
| Temperature [K] | 100 |
| Detector technology | PIXEL |
| Collection date | 2021-02-04 |
| Detector | DECTRIS EIGER X 16M |
| Wavelength(s) | 1.000 |
| Spacegroup name | P 65 2 2 |
| Unit cell lengths | 79.387, 79.387, 215.003 |
| Unit cell angles | 90.00, 90.00, 120.00 |
Refinement procedure
| Resolution | 49.610 - 3.500 |
| R-factor | 0.2496 |
| Rwork | 0.247 |
| R-free | 0.27180 |
| Structure solution method | MOLECULAR REPLACEMENT |
| Starting model (for MR) | 2wa0 |
| Data reduction software | HKL-2000 |
| Data scaling software | HKL-2000 |
| Phasing software | PHASER |
| Refinement software | PHENIX (1.19.2_4158) |
Data quality characteristics
| Overall | Outer shell | |
| Low resolution limit [Å] | 50.000 | 3.626 |
| High resolution limit [Å] | 3.500 | 3.500 |
| Number of reflections | 5488 | 5248 |
| <I/σ(I)> | 8.65 | |
| Completeness [%] | 98.2 | |
| Redundancy | 10.5 | |
| CC(1/2) | 0.992 | 0.967 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | VAPOR DIFFUSION, SITTING DROP | 293 | Tris-HCl, magnesium chloride, ethanol |