Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

7UC6

Stat5a Core in complex with Compound 12

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsAPS BEAMLINE 21-ID-F
Synchrotron siteAPS
Beamline21-ID-F
Temperature [K]100
Detector technologyCCD
Collection date2021-03-24
DetectorRAYONIX MX-300
Wavelength(s)0.9787
Spacegroup nameH 3 2
Unit cell lengths237.674, 237.674, 112.811
Unit cell angles90.00, 90.00, 120.00
Refinement procedure
Resolution46.820 - 3.101
R-factor0.1972
Rwork0.195
R-free0.24290
Structure solution methodMOLECULAR REPLACEMENT
RMSD bond length0.008
RMSD bond angle1.020
Data reduction softwareHKL-2000
Data scaling softwareHKL-2000
Phasing softwarePHASER
Refinement softwareBUSTER (2.10.4 (3-FEB-2022))
Data quality characteristics
 OverallInner shellOuter shell
Low resolution limit [Å]50.00050.0003.150
High resolution limit [Å]3.1008.4003.100
Rmerge0.1300.0311.403
Rmeas0.1360.0321.468
Rpim0.0400.0100.433
Total number of observations253749
Number of reflections2221211681110
<I/σ(I)>5.3
Completeness [%]100.099.9100
Redundancy11.410.511.5
CC(1/2)0.9990.912
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, SITTING DROP2931.1M Sodium Malonate pH 7.0, 0.1M Hepes pH 7.0, 0.5% Jeffamine ED-2001 pH 7.0

219869

PDB entries from 2024-05-15

PDB statisticsPDBj update infoContact PDBjnumon