Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | ROTATING ANODE |
Source details | RIGAKU FR-D |
Temperature [K] | 100 |
Detector technology | CCD |
Collection date | 2014-12-01 |
Detector | RIGAKU SATURN A200 |
Wavelength(s) | 1.542 |
Spacegroup name | C 1 2 1 |
Unit cell lengths | 141.900, 64.960, 116.140 |
Unit cell angles | 90.00, 103.59, 90.00 |
Refinement procedure
Resolution | 31.024 - 2.300 |
Rwork | 0.208 |
R-free | 0.30620 |
Structure solution method | MOLECULAR REPLACEMENT |
Starting model (for MR) | Internal Model |
RMSD bond length | 0.005 |
RMSD bond angle | 1.356 |
Data reduction software | iMOSFLM |
Data scaling software | Aimless |
Phasing software | MOLREP |
Refinement software | REFMAC (5.8.0267) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 31.210 | 2.380 |
High resolution limit [Å] | 2.300 | 2.300 |
Rmerge | 0.153 | 0.345 |
Number of reflections | 45929 | 4484 |
<I/σ(I)> | 7.6 | |
Completeness [%] | 99.9 | |
Redundancy | 2.5 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION | 293 | ethylene glycol per PEG 8000, carboxylic acids mix, buffer system 2 |