Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

7N8M

PptT PAP(CoA) 8978B complex

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsAPS BEAMLINE 19-ID
Synchrotron siteAPS
Beamline19-ID
Temperature [K]120
Detector technologyPIXEL
Collection date2017-08-06
DetectorDECTRIS PILATUS3 S 6M
Wavelength(s)0.98
Spacegroup nameC 1 2 1
Unit cell lengths134.759, 63.709, 79.669
Unit cell angles90.00, 123.33, 90.00
Refinement procedure
Resolution39.790 - 1.570
R-factor0.1727
Rwork0.172
R-free0.20170
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)6ct5
RMSD bond length0.009
RMSD bond angle0.993
Data reduction softwareHKL-3000
Data scaling softwareHKL-3000
Phasing softwarePHASER
Refinement softwarePHENIX (dev_3126)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]39.7901.625
High resolution limit [Å]1.5701.570
Number of reflections784677824
<I/σ(I)>27.8
Completeness [%]99.699.48
Redundancy4.9
CC(1/2)0.9490.779
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, HANGING DROP6.7291.150.1 M Bis-Tris Propane pH 6.7, 1.8M Magnesium Sulfate

219869

PDB entries from 2024-05-15

PDB statisticsPDBj update infoContact PDBjnumon