7N1E
SARS-CoV-2 RLQ peptide-specific TCR pRLQ3 binds to RLQ-HLA-A2
Experimental procedure
| Experimental method | SINGLE WAVELENGTH |
| Source type | SYNCHROTRON |
| Source details | APS BEAMLINE 23-ID-D |
| Synchrotron site | APS |
| Beamline | 23-ID-D |
| Temperature [K] | 100 |
| Detector technology | PIXEL |
| Collection date | 2021-03-14 |
| Detector | DECTRIS PILATUS3 S 6M |
| Wavelength(s) | 1.0 |
| Spacegroup name | P 1 21 1 |
| Unit cell lengths | 52.799, 68.150, 148.598 |
| Unit cell angles | 90.00, 94.61, 90.00 |
Refinement procedure
Data quality characteristics
| Overall | Outer shell | |
| Low resolution limit [Å] | 49.400 | 2.380 |
| High resolution limit [Å] | 2.300 | 2.300 |
| Number of reflections | 159246 | 15350 |
| <I/σ(I)> | 12.6 | |
| Completeness [%] | 99.2 | |
| Redundancy | 3.4 | |
| CC(1/2) | 0.952 | 0.753 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | VAPOR DIFFUSION, HANGING DROP | 6 | 295 | 0.2M Ammonium sulfate, 0.1M MES (pH 6.0), 12% (w/v) PEG 4000 |