7EPM
human LDHC complexed with NAD+ and ethylamino acetic acid
Experimental procedure
| Experimental method | SINGLE WAVELENGTH |
| Source type | SYNCHROTRON |
| Source details | SSRF BEAMLINE BL19U1 |
| Synchrotron site | SSRF |
| Beamline | BL19U1 |
| Temperature [K] | 100 |
| Detector technology | PIXEL |
| Collection date | 2018-10-22 |
| Detector | DECTRIS PILATUS 6M |
| Wavelength(s) | 0.9789 |
| Spacegroup name | P 61 2 2 |
| Unit cell lengths | 177.891, 177.891, 179.210 |
| Unit cell angles | 90.00, 90.00, 120.00 |
Refinement procedure
| Resolution | 44.470 - 3.000 |
| R-factor | 0.2044 |
| Rwork | 0.203 |
| R-free | 0.22650 |
| Structure solution method | MOLECULAR REPLACEMENT |
| Starting model (for MR) | 1i10 |
| RMSD bond length | 0.011 |
| RMSD bond angle | 1.188 |
| Data reduction software | HKL-3000 |
| Data scaling software | HKL-2000 |
| Phasing software | PHASER |
| Refinement software | PHENIX (1.15.2_3472) |
Data quality characteristics
| Overall | Outer shell | |
| Low resolution limit [Å] | 50.000 | 3.070 |
| High resolution limit [Å] | 2.998 | 2.998 |
| Number of reflections | 34121 | 2229 |
| <I/σ(I)> | 15 | |
| Completeness [%] | 100.0 | |
| Redundancy | 21.3 | |
| CC(1/2) | 0.987 | 0.602 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | VAPOR DIFFUSION, HANGING DROP | 7.5 | 293 | 0.1 M sodium chloride, 0.1 M HEPES pH 7.5, 1.6 M ammonium sulfate |