Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

7COD

Post insertion complex of DNA polymerase Mu (K438A/Q441A) with 1-nt gapped DNA

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsSSRF BEAMLINE BL17U
Synchrotron siteSSRF
BeamlineBL17U
Temperature [K]95
Detector technologyCCD
Collection date2019-12-30
DetectorADSC QUANTUM 315r
Wavelength(s)0.9792
Spacegroup nameP 21 21 21
Unit cell lengths60.180, 68.520, 111.910
Unit cell angles90.00, 90.00, 90.00
Refinement procedure
Resolution29.773 - 1.800
R-factor0.1868
Rwork0.186
R-free0.21090
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)4m04
Data reduction softwareXDS
Data scaling softwareXSCALE
Phasing softwarePHASER
Refinement softwarePHENIX (1.13_2998)
Data quality characteristics
 OverallInner shellOuter shell
Low resolution limit [Å]29.77329.7731.850
High resolution limit [Å]1.8008.0501.800
Rmerge0.0360.0170.303
Rmeas0.0400.0200.383
Total number of observations195058
Number of reflections414955462264
<I/σ(I)>24.1960.162.55
Completeness [%]95.196.171.5
Redundancy4.7014.3592.223
CC(1/2)1.0000.9990.893
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION82981,4-Dioxane, Tris-Hcl, PEG 3350

219869

PDB entries from 2024-05-15