Loading
PDBj
MenuPDBj@FacebookPDBj@X(formerly Twitter)PDBj@BlueSkyPDBj@YouTubewwPDB FoundationwwPDBDonate
RCSB PDBPDBeBMRBAdv. SearchSearch help

6YT7

GLYCOSYLATED KNOB/DUMMY-HOLE FC FRAGMENT

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsSLS BEAMLINE X10SA
Synchrotron siteSLS
BeamlineX10SA
Temperature [K]100
Detector technologyPIXEL
Collection date2018-07-13
DetectorDECTRIS PILATUS3 6M
Wavelength(s)1.0000
Spacegroup nameP 21 21 21
Unit cell lengths49.015, 75.103, 149.445
Unit cell angles90.00, 90.00, 90.00
Refinement procedure
Resolution67.110 - 1.550
R-factor0.236
Rwork0.234
R-free0.27310
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)5hy9
Data reduction softwareXDS
Data scaling softwareAimless
Phasing softwarePHASER
Refinement softwarePHENIX (dev_3893)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]74.8301.690
High resolution limit [Å]1.5501.550
Rpim0.020
Number of reflections643773224
<I/σ(I)>23.11.6
Completeness [%]95.461.8
Redundancy6.66.9
CC(1/2)1.0000.700
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, SITTING DROP7.529425% (w/v) PEG2000 MME, 0.1M HEPES

237423

PDB entries from 2025-06-11

PDB statisticsPDBj update infoContact PDBjnumon