6YT7
GLYCOSYLATED KNOB/DUMMY-HOLE FC FRAGMENT
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | SLS BEAMLINE X10SA |
Synchrotron site | SLS |
Beamline | X10SA |
Temperature [K] | 100 |
Detector technology | PIXEL |
Collection date | 2018-07-13 |
Detector | DECTRIS PILATUS3 6M |
Wavelength(s) | 1.0000 |
Spacegroup name | P 21 21 21 |
Unit cell lengths | 49.015, 75.103, 149.445 |
Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
Resolution | 67.110 - 1.550 |
R-factor | 0.236 |
Rwork | 0.234 |
R-free | 0.27310 |
Structure solution method | MOLECULAR REPLACEMENT |
Starting model (for MR) | 5hy9 |
Data reduction software | XDS |
Data scaling software | Aimless |
Phasing software | PHASER |
Refinement software | PHENIX (dev_3893) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 74.830 | 1.690 |
High resolution limit [Å] | 1.550 | 1.550 |
Rpim | 0.020 | |
Number of reflections | 64377 | 3224 |
<I/σ(I)> | 23.1 | 1.6 |
Completeness [%] | 95.4 | 61.8 |
Redundancy | 6.6 | 6.9 |
CC(1/2) | 1.000 | 0.700 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, SITTING DROP | 7.5 | 294 | 25% (w/v) PEG2000 MME, 0.1M HEPES |