6Y58
Binary complex of 14-3-3 sigma (C38N) with the Estrogen Related Receptor gamma (LBD) phosphopeptide
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SEALED TUBE |
Source details | RIGAKU MICROMAX-003 |
Temperature [K] | 100 |
Detector technology | PIXEL |
Collection date | 2017-01-04 |
Detector | DECTRIS PILATUS 200K |
Wavelength(s) | 1.54 |
Spacegroup name | C 2 2 21 |
Unit cell lengths | 82.297, 111.690, 62.593 |
Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
Resolution | 33.127 - 1.904 |
R-factor | 0.1762 |
Rwork | 0.174 |
R-free | 0.20880 |
Structure solution method | MOLECULAR REPLACEMENT |
Starting model (for MR) | 3p1n |
Data reduction software | DIALS |
Data scaling software | Aimless |
Phasing software | MOLREP |
Refinement software | PHENIX (1.15.2_3472) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 45.430 | 1.940 |
High resolution limit [Å] | 1.900 | 1.900 |
Number of reflections | 22781 | 1659 |
<I/σ(I)> | 8.6 | 3 |
Completeness [%] | 99.3 | |
Redundancy | 4 | |
CC(1/2) | 0.992 | 0.873 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, HANGING DROP | 277 | 0.095 M HEPES (pH 7.1), 0.19 M CaCl2, 27% (v/v) PEG 400 and 5% (v/v) glycerol |