6W7E
K2P2.1 (TREK-1), 30 mM K+
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | APS BEAMLINE 23-ID-D |
Synchrotron site | APS |
Beamline | 23-ID-D |
Temperature [K] | 100 |
Detector technology | PIXEL |
Collection date | 2018-03-07 |
Detector | DECTRIS PILATUS 6M |
Wavelength(s) | 1.03320 |
Spacegroup name | P 21 21 21 |
Unit cell lengths | 67.368, 122.534, 126.552 |
Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
Resolution | 14.940 - 3.290 |
R-factor | 0.289 |
Rwork | 0.288 |
R-free | 0.30720 |
Structure solution method | MOLECULAR REPLACEMENT |
Starting model (for MR) | 6cq6 |
RMSD bond length | 0.026 |
RMSD bond angle | 0.950 |
Data reduction software | XDS |
Data scaling software | Aimless |
Phasing software | PHASER |
Refinement software | BUSTER (2.10.3 (6-FEB-2020)) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 46.120 | 3.550 |
High resolution limit [Å] | 3.290 | 3.290 |
Rmerge | 0.052 | |
Number of reflections | 16609 | 3367 |
<I/σ(I)> | 17.4 | |
Completeness [%] | 99.9 | |
Redundancy | 11.7 | |
CC(1/2) | 0.326 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, HANGING DROP | 8 | 277 | 22-25% PEG400, 100mM HEPES pH=8.0, 1mM CdCl2, 200mM KCl |