6W7B
K2P2.1 (TREK-1), 0 mM K+
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | APS BEAMLINE 23-ID-D |
Synchrotron site | APS |
Beamline | 23-ID-D |
Temperature [K] | 100 |
Detector technology | PIXEL |
Collection date | 2018-01-18 |
Detector | DECTRIS PILATUS3 6M |
Wavelength(s) | 1.03320 |
Spacegroup name | P 21 21 21 |
Unit cell lengths | 66.906, 122.597, 125.576 |
Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
Resolution | 14.960 - 3.880 |
R-factor | 0.2764 |
Rwork | 0.275 |
R-free | 0.30870 |
Structure solution method | MOLECULAR REPLACEMENT |
Starting model (for MR) | 6cq6 |
RMSD bond length | 0.006 |
RMSD bond angle | 0.840 |
Data reduction software | Aimless |
Data scaling software | XDS |
Phasing software | PHASER |
Refinement software | BUSTER (2.10.3 (6-FEB-2020)) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 45.800 | 4.000 |
High resolution limit [Å] | 3.880 | 3.880 |
Rmerge | 0.196 | |
Number of reflections | 10002 | 2771 |
<I/σ(I)> | 2.95 | |
Completeness [%] | 99.3 | |
Redundancy | 4.9 | |
CC(1/2) | 0.264 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, HANGING DROP | 277 | 22-25% PEG400, 100mM HEPES pH=8.0, 1mM CdCl2, 200mM KCl |