Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

6W7B

K2P2.1 (TREK-1), 0 mM K+

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsAPS BEAMLINE 23-ID-D
Synchrotron siteAPS
Beamline23-ID-D
Temperature [K]100
Detector technologyPIXEL
Collection date2018-01-18
DetectorDECTRIS PILATUS3 6M
Wavelength(s)1.03320
Spacegroup nameP 21 21 21
Unit cell lengths66.906, 122.597, 125.576
Unit cell angles90.00, 90.00, 90.00
Refinement procedure
Resolution14.960 - 3.880
R-factor0.2764
Rwork0.275
R-free0.30870
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)6cq6
RMSD bond length0.006
RMSD bond angle0.840
Data reduction softwareAimless
Data scaling softwareXDS
Phasing softwarePHASER
Refinement softwareBUSTER (2.10.3 (6-FEB-2020))
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]45.8004.000
High resolution limit [Å]3.8803.880
Rmerge0.196
Number of reflections100022771
<I/σ(I)>2.95
Completeness [%]99.3
Redundancy4.9
CC(1/2)0.264
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, HANGING DROP27722-25% PEG400, 100mM HEPES pH=8.0, 1mM CdCl2, 200mM KCl

227111

PDB entries from 2024-11-06

PDB statisticsPDBj update infoContact PDBjnumon