Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

6VDC

POL domain of Pol1 from M. smegmatis

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsAPS BEAMLINE 24-ID-C
Synchrotron siteAPS
Beamline24-ID-C
Temperature [K]100
Detector technologyPIXEL
Collection date2018-10-31
DetectorDECTRIS PILATUS3 S 6M
Wavelength(s)0.97918
Spacegroup nameC 2 2 21
Unit cell lengths62.591, 150.951, 150.348
Unit cell angles90.00, 90.00, 90.00
Refinement procedure
Resolution45.830 - 2.402
R-factor0.2226
Rwork0.219
R-free0.26550
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)4uqg
Data reduction softwareHKL-2000
Data scaling softwareHKL-2000
Phasing softwarePHENIX
Refinement softwarePHENIX (1.14_3260)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]50.0002.440
High resolution limit [Å]2.4002.400
Rpim0.0300.312
Number of reflections280691368
<I/σ(I)>33.6
Completeness [%]99.1
Redundancy6.3
CC(1/2)0.9960.869
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, SITTING DROP2930.2 M magnesium chloride, 20% PEG3350

222926

PDB entries from 2024-07-24

PDB statisticsPDBj update infoContact PDBjnumon