6US2
MTH1 in complex with compound 5
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | ROTATING ANODE |
Source details | RIGAKU MICROMAX-007 |
Temperature [K] | 100 |
Detector technology | IMAGE PLATE |
Collection date | 2014-08-28 |
Detector | RIGAKU RAXIS IV++ |
Wavelength(s) | 1.54178 |
Spacegroup name | P 2 21 21 |
Unit cell lengths | 36.315, 59.953, 66.672 |
Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
Resolution | 31.891 - 1.800 |
R-factor | 0.181741061345 |
Rwork | 0.176 |
R-free | 0.23442 |
Structure solution method | MOLECULAR REPLACEMENT |
Starting model (for MR) | 3zr0 |
RMSD bond length | 0.008 |
RMSD bond angle | 1.181 |
Data reduction software | HKL-2000 |
Data scaling software | HKL-2000 |
Phasing software | PHENIX |
Refinement software | PHENIX (1.9_1692) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 50.000 | 1.830 |
High resolution limit [Å] | 1.800 | 1.800 |
Rmerge | 0.084 | 0.508 |
Number of reflections | 14073 | 643 |
<I/σ(I)> | 15.6 | |
Completeness [%] | 99.9 | |
Redundancy | 3.7 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, HANGING DROP | 293 | 30% PEG 6000, 0.1M sodium acetate pH 4.0, 0.2M lithium sulfate |