6UG9
Complex of ch28/11 Fab and SSEA-4 (hexagonal form)
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | AUSTRALIAN SYNCHROTRON BEAMLINE MX2 |
Synchrotron site | Australian Synchrotron |
Beamline | MX2 |
Temperature [K] | 100 |
Detector technology | PIXEL |
Collection date | 2018-04-16 |
Detector | DECTRIS EIGER X 16M |
Wavelength(s) | 0.954 |
Spacegroup name | P 64 |
Unit cell lengths | 169.952, 169.952, 95.435 |
Unit cell angles | 90.00, 90.00, 120.00 |
Refinement procedure
Resolution | 50.000 - 2.740 |
R-factor | 0.1735 |
Rwork | 0.170 |
R-free | 0.24690 |
Structure solution method | MOLECULAR REPLACEMENT |
Starting model (for MR) | 6ug7 |
RMSD bond length | 0.012 |
RMSD bond angle | 1.673 |
Data reduction software | XDS |
Data scaling software | XSCALE |
Phasing software | PHENIX |
Refinement software | REFMAC (5.8.0155) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 50.000 | 2.800 |
High resolution limit [Å] | 2.740 | 2.740 |
Rmeas | 0.140 | 0.770 |
Number of reflections | 41405 | 6561 |
<I/σ(I)> | 10.6 | |
Completeness [%] | 99.7 | |
Redundancy | 5.3 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, HANGING DROP | 7.5 | 291 | PEG 4000, iso-Propanol, sodium HEPES |