Human 14-3-3 sigma isoform in complex with PLP

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsDIAMOND BEAMLINE I04-1
Synchrotron siteDiamond
BeamlineI04-1
Temperature [K]100
Detector technologyPIXEL
Collection date2018-04-29
DetectorDECTRIS PILATUS3 6M
Wavelength(s)0.9159
Spacegroup nameP 21 21 21
Unit cell lengths63.270, 102.660, 157.300
Unit cell angles90.00, 90.00, 90.00
Refinement procedure
Resolution78.650 - 3.000
R-factor0.216
Rwork0.214
R-free0.26900
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)1yz5
RMSD bond length0.010
RMSD bond angle1.788
Data reduction softwareiMOSFLM
Data scaling softwareSCALA
Phasing softwareMOLREP
Refinement softwareREFMAC (5.8.0257)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]85.9703.160
High resolution limit [Å]3.0003.000
Rmerge0.1980.608
Number of reflections210853016
<I/σ(I)>7.82.1
Completeness [%]99.499.5
Redundancy54.7
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, HANGING DROP928140 % wt/vol PEG 4000, 600mM ammonium sulfate, 100 mM Tris-HCl, pH 9.0

222415