6SQZ

Mouse dCTPase in complex with dCMPNPP

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsBESSY BEAMLINE 14.1
Synchrotron siteBESSY
Beamline14.1
Temperature [K]100
Detector technologyPIXEL
Collection date2015-12-08
DetectorDECTRIS PILATUS 6M
Wavelength(s)0.8726
Spacegroup nameP 41 21 2
Unit cell lengths58.997, 58.997, 142.650
Unit cell angles90.00, 90.00, 90.00
Refinement procedure
Resolution54.520 - 1.900
R-factor0.1883
Rwork0.187
R-free0.21710
Structure solution methodMOLECULAR REPLACEMENT
RMSD bond length0.014
RMSD bond angle1.648
Data reduction softwareXDS
Data scaling softwareAimless
Phasing softwarePHASER
Refinement softwareREFMAC (5.8.0158)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]55.0002.050
High resolution limit [Å]1.9001.900
Rmerge0.1001.140
Number of reflections206632015
<I/σ(I)>18.2
Completeness [%]100.0
Redundancy13.5
CC(1/2)0.9900.640
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, SITTING DROP2910.1 M Tris pH 8.0, 2.2 M ammonium sulfate

248335