6PAG
Killer cell immunoglobulin-like receptor 2DL3 in complex with HLA-C*07:02
Experimental procedure
| Experimental method | SINGLE WAVELENGTH |
| Source type | SYNCHROTRON |
| Source details | AUSTRALIAN SYNCHROTRON BEAMLINE MX2 |
| Synchrotron site | Australian Synchrotron |
| Beamline | MX2 |
| Temperature [K] | 100 |
| Detector technology | CCD |
| Collection date | 2014-10-15 |
| Detector | ADSC QUANTUM 315 |
| Wavelength(s) | 0.954 |
| Spacegroup name | P 64 |
| Unit cell lengths | 111.855, 111.855, 87.994 |
| Unit cell angles | 90.00, 90.00, 120.00 |
Refinement procedure
| Resolution | 32.567 - 2.501 |
| R-factor | 0.2242 |
| Rwork | 0.223 |
| R-free | 0.25410 |
| Structure solution method | MOLECULAR REPLACEMENT |
| Starting model (for MR) | 1efx |
| RMSD bond length | 0.046 |
| RMSD bond angle | 1.691 |
| Data reduction software | MOSFLM |
| Data scaling software | SCALA |
| Phasing software | PHASER |
| Refinement software | PHENIX (1.8.1_1168) |
Data quality characteristics
| Overall | Outer shell | |
| Low resolution limit [Å] | 50.000 | 2.600 |
| High resolution limit [Å] | 2.500 | 2.500 |
| Number of reflections | 21403 | 2136 |
| <I/σ(I)> | 14.2 | |
| Completeness [%] | 98.5 | 98.7 |
| Redundancy | 3.1 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | VAPOR DIFFUSION, HANGING DROP | 8 | 293 | 0.2 M Ammonium acetate, 0.1 M Tris-HCl pH.8.0 and 25% PEG 3350. |