6OPG
phosphorylated ERK2 with AMP-PNP
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | ROTATING ANODE |
Source details | RIGAKU FR-E |
Temperature [K] | 100 |
Detector technology | IMAGE PLATE |
Collection date | 2012-05-01 |
Detector | RIGAKU RAXIS IV++ |
Wavelength(s) | 1.5418 |
Spacegroup name | P 21 21 21 |
Unit cell lengths | 41.850, 77.150, 152.160 |
Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
Resolution | 23.890 - 2.900 |
R-factor | 0.16039 |
Rwork | 0.156 |
R-free | 0.23907 |
Structure solution method | MOLECULAR REPLACEMENT |
Starting model (for MR) | 2erk |
RMSD bond length | 0.009 |
RMSD bond angle | 1.673 |
Data reduction software | MOSFLM |
Data scaling software | Aimless |
Phasing software | PHASER |
Refinement software | REFMAC (5.8.0238) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 23.900 | 3.060 |
High resolution limit [Å] | 2.900 | 2.900 |
Rmerge | 0.107 | 0.316 |
Rmeas | 0.342 | |
Rpim | 0.129 | |
Number of reflections | 11508 | 1636 |
<I/σ(I)> | 6.6 | 2.5 |
Completeness [%] | 99.7 | 99.5 |
Redundancy | 6.7 | 6.9 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, HANGING DROP | 8.8 | 293 | 36% PEG3350, 0.1 M Tris pH 8.8 10mg/mL protein. |