Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

6MSC

Novel, potent, selective and brain penetrant phosphodiesterase 10A inhibitors

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsAPS BEAMLINE 17-ID
Synchrotron siteAPS
Beamline17-ID
Temperature [K]100
Detector technologyPIXEL
Collection date2018-06-06
DetectorDECTRIS PILATUS 6M
Wavelength(s)1.0
Spacegroup nameP 21 21 21
Unit cell lengths50.530, 81.810, 159.400
Unit cell angles90.00, 90.00, 90.00
Refinement procedure
Resolution72.780 - 2.360
R-factor0.208
Rwork0.206
R-free0.24200
Structure solution methodMOLECULAR REPLACEMENT
RMSD bond length0.010
RMSD bond angle1.050
Data reduction softwareXDS
Data scaling softwareXDS
Phasing softwarePHASER
Refinement softwareBUSTER (2.11.7)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]79.7002.404
High resolution limit [Å]2.3602.364
Rmerge0.0751.297
Number of reflections277791385
<I/σ(I)>15
Completeness [%]99.799.6
Redundancy6.46.6
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION2775% Tascimate pH7.0, 100mM HEPES pH7, 10% PMME5000

222926

PDB entries from 2024-07-24