Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

6LSZ

HSP 90 in complex with Ganetespib

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsSSRF BEAMLINE BL17U1
Synchrotron siteSSRF
BeamlineBL17U1
Temperature [K]100
Detector technologyPIXEL
Collection date2018-04-21
DetectorDECTRIS EIGER X 16M
Wavelength(s)0.979
Spacegroup nameI 2 2 2
Unit cell lengths65.692, 89.377, 99.496
Unit cell angles90.00, 90.00, 90.00
Refinement procedure
Resolution44.689 - 1.992
R-factor0.1854
Rwork0.183
R-free0.20780
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)3tuh
RMSD bond length0.009
RMSD bond angle0.977
Data reduction softwareHKL-3000
Data scaling softwareHKL-3000
Phasing softwarePHASER
Refinement softwarePHENIX (1.11.1_2575)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]50.0002.020
High resolution limit [Å]1.9901.990
Number of reflections203811932
<I/σ(I)>4.9
Completeness [%]99.0
Redundancy6.6
CC(1/2)0.9910.677
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, SITTING DROP287100 mM Tris-HCl (pH 8.5) 200 mM MgCl2 25% PEG4000

221716

PDB entries from 2024-06-26

PDB statisticsPDBj update infoContact PDBjnumon