6JUQ
mutant PolIV-DNA incoming nucleotide complex 2
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | ESRF BEAMLINE ID29 |
Synchrotron site | ESRF |
Beamline | ID29 |
Temperature [K] | 100 |
Detector technology | PIXEL |
Collection date | 2018-07-27 |
Detector | DECTRIS PILATUS 6M-F |
Wavelength(s) | 1.0723 |
Spacegroup name | P 1 21 1 |
Unit cell lengths | 86.151, 57.244, 110.793 |
Unit cell angles | 90.00, 92.26, 90.00 |
Refinement procedure
Resolution | 86.010 - 2.740 |
R-factor | 0.2279 |
Rwork | 0.226 |
R-free | 0.27084 |
Structure solution method | MOLECULAR REPLACEMENT |
Starting model (for MR) | 4irc |
RMSD bond length | 0.019 |
RMSD bond angle | 1.665 |
Data reduction software | MOSFLM |
Data scaling software | SCALA |
Phasing software | PHASER |
Refinement software | REFMAC (5.8.0155) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 86.010 | 2.890 |
High resolution limit [Å] | 2.740 | 2.740 |
Rmerge | 0.104 | |
Number of reflections | 28806 | 4105 |
<I/σ(I)> | 8.9 | |
Completeness [%] | 99.5 | 98.2 |
Redundancy | 6.5 | 6.7 |
CC(1/2) | 0.997 | 0.475 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, SITTING DROP | 4.7 | 277 | MDP 1%, Phosphate buffer ph 4.7 |