Loading
PDBj
MenuPDBj@FacebookPDBj@X(formerly Twitter)PDBj@BlueSkyPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

6HUT

GFP8 - a stabilized variant of cycle-3 GFP

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsDIAMOND BEAMLINE I04-1
Synchrotron siteDiamond
BeamlineI04-1
Temperature [K]100
Detector technologyPIXEL
Collection date2017-05-07
DetectorDECTRIS PILATUS 6M-F
Wavelength(s)0.9282
Spacegroup nameP 21 21 21
Unit cell lengths52.160, 63.370, 69.210
Unit cell angles90.00, 90.00, 90.00
Refinement procedure
Resolution31.685 - 1.290
Rwork0.186
R-free0.20340
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)4lqt
Phasing softwareAMoRE (CCP4 7.0)
Refinement softwarePHENIX (1.11.1-2575)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]35.0001.490
High resolution limit [Å]1.1501.450
Rmeas0.634
Number of reflections582482865
<I/σ(I)>20.22.6
Completeness [%]99.695.3
Redundancy7.97.9
CC(1/2)1.0000.200
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, HANGING DROP7.5296200 mM HEPES, 10% v/v isopropanol, 200 mM NaCl

227344