6GY1
rat COMT in complex with inhibitor
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | ROTATING ANODE |
Source details | RIGAKU |
Temperature [K] | 100 |
Detector technology | IMAGE PLATE |
Collection date | 2014-04-23 |
Detector | MAR scanner 345 mm plate |
Wavelength(s) | 1.54179 |
Spacegroup name | P 32 2 1 |
Unit cell lengths | 50.410, 50.410, 168.332 |
Unit cell angles | 90.00, 90.00, 120.00 |
Refinement procedure
Resolution | 42.258 - 2.100 |
R-factor | 0.2141 |
Rwork | 0.212 |
R-free | 0.24890 |
Structure solution method | MOLECULAR REPLACEMENT |
Starting model (for MR) | 3s68 |
Data reduction software | MOSFLM |
Data scaling software | SCALA (3.3.21) |
Phasing software | PHASER |
Refinement software | PHENIX |
Data quality characteristics
Overall | Inner shell | Outer shell | |
Low resolution limit [Å] | 56.111 | 42.258 | 2.210 |
High resolution limit [Å] | 2.100 | 6.640 | 2.100 |
Rmerge | 0.040 | 0.303 | |
Rmeas | 0.086 | 0.048 | 0.359 |
Rpim | 0.045 | 0.026 | 0.189 |
Total number of observations | 51463 | ||
Number of reflections | 15123 | 570 | 2140 |
<I/σ(I)> | 8 | 11.6 | 2.5 |
Completeness [%] | 99.3 | 98.4 | 99.5 |
Redundancy | 3.4 | 3 | 3.5 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, HANGING DROP | 291 | 100 mM Bis-Tris propane, 100 mM NaCl, 1.2-1.8 M (NH4)2SO4 |