Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

6G6W

HUMAN PI3KDELTA IN COMPLEX WITH LIGAND LASW1976

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsSLS BEAMLINE X06SA
Synchrotron siteSLS
BeamlineX06SA
Temperature [K]100
Detector technologyPIXEL
Collection date2013-07-25
DetectorDECTRIS PILATUS 6M
Wavelength(s)0.9999
Spacegroup nameP 21 21 21
Unit cell lengths90.452, 108.951, 142.481
Unit cell angles90.00, 90.00, 90.00
Refinement procedure
Resolution86.570 - 2.720
R-factor0.219
Rwork0.218
R-free0.26010
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)pdbid 2WXR
RMSD bond length0.009
RMSD bond angle1.250
Data reduction softwareXDS
Data scaling softwareXSCALE
Phasing softwarePHASER
Refinement softwareREFMAC (5.6.0117)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]86.5702.970
High resolution limit [Å]2.7202.720
Rmerge0.0380.440
Number of reflections38495
<I/σ(I)>30.3
Completeness [%]99.999.9
Redundancy8.18.2
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, HANGING DROP7.5293PEG

222926

PDB entries from 2024-07-24

PDB statisticsPDBj update infoContact PDBjnumon