Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

6FZP

PPAR gamma complex.

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsESRF BEAMLINE ID30B
Synchrotron siteESRF
BeamlineID30B
Temperature [K]100
Detector technologyPIXEL
Collection date2017-10-20
DetectorDECTRIS PILATUS 6M
Wavelength(s)0.968
Spacegroup nameC 2 2 21
Unit cell lengths53.592, 86.268, 122.693
Unit cell angles90.00, 90.00, 90.00
Refinement procedure
Resolution17.320 - 2.300
R-factor0.219
Rwork0.219
R-free0.25200
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)1prg
Data reduction softwareXDS
Data scaling softwareXDS
Phasing softwarePHENIX
Refinement softwarePHENIX (1.12_2829)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]17.3202.380
High resolution limit [Å]2.3002.300
Rmerge0.016
Number of reflections125561238
<I/σ(I)>19.73
Completeness [%]96.6
Redundancy2
CC(1/2)0.914
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, SITTING DROP7.5290NH4 acetate 0.3M, Hepes 0.1M pH 7.5, di-sodium tartrate 0.8 M

219140

PDB entries from 2024-05-01

PDB statisticsPDBj update infoContact PDBjnumon