6EOQ
DPP9 - Apo
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | SLS BEAMLINE X06SA |
Synchrotron site | SLS |
Beamline | X06SA |
Temperature [K] | 100 |
Detector technology | PIXEL |
Collection date | 2017-09-21 |
Detector | DECTRIS PILATUS 6M-F |
Wavelength(s) | 0.99997 |
Spacegroup name | P 1 21 1 |
Unit cell lengths | 120.370, 118.020, 164.460 |
Unit cell angles | 90.00, 105.49, 90.00 |
Refinement procedure
Resolution | 49.260 - 3.000 |
R-factor | 0.27605 |
Rwork | 0.273 |
R-free | 0.33414 |
Structure solution method | MOLECULAR REPLACEMENT |
Starting model (for MR) | 1orv |
RMSD bond length | 0.010 |
RMSD bond angle | 1.365 |
Data reduction software | XDS |
Data scaling software | XSCALE |
Phasing software | PHASER |
Refinement software | REFMAC (5.8.0155) |
Data quality characteristics
Overall | |
Low resolution limit [Å] | 49.260 |
High resolution limit [Å] | 3.000 |
Number of reflections | 88848 |
<I/σ(I)> | 5.3 |
Completeness [%] | 99.8 |
Redundancy | 13.57 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, HANGING DROP | 293 | 10%PEG 8000, 25% Glycerol, 0.16M Calcium Acetate, 0.08M Caodilate pH6.25, |