6DRY
Structural Determinants of Activation and Biased Agonism at the 5-HT2B Receptor
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | APS BEAMLINE 23-ID-B |
Synchrotron site | APS |
Beamline | 23-ID-B |
Temperature [K] | 100 |
Detector technology | PIXEL |
Collection date | 2016-08-04 |
Detector | DECTRIS EIGER X 16M |
Wavelength(s) | 1.033 |
Spacegroup name | C 2 2 21 |
Unit cell lengths | 59.662, 119.452, 171.021 |
Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
Resolution | 29.681 - 2.918 |
R-factor | 0.2363 |
Rwork | 0.235 |
R-free | 0.27170 |
Structure solution method | MOLECULAR REPLACEMENT |
Starting model (for MR) | : 4IB4 |
RMSD bond length | 0.002 |
RMSD bond angle | 0.626 |
Data reduction software | HKL-3000 |
Data scaling software | HKL-3000 |
Phasing software | PHASER |
Refinement software | PHENIX (1.12_2829) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 30.000 | 2.990 |
High resolution limit [Å] | 2.900 | 2.900 |
Rmerge | 0.157 | 0.718 |
Number of reflections | 12467 | 905 |
<I/σ(I)> | 7.7 | 1.4 |
Completeness [%] | 91.8 | 81.1 |
Redundancy | 2.6 | 2.1 |
CC(1/2) | 0.980 | 0.560 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | LIPIDIC CUBIC PHASE | 293 | 100 mM Tris/HCl pH 7.2-8.0, 170-190 mM Potassium phosphate monobasic, 30% v/v PEG400 |