6DC5
RSV prefusion F in complex with AM22 Fab
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | NSLS BEAMLINE X6A |
Synchrotron site | NSLS |
Beamline | X6A |
Temperature [K] | 100 |
Detector technology | CCD |
Collection date | 2014-07-31 |
Detector | ADSC QUANTUM 270 |
Wavelength(s) | 1.000 |
Spacegroup name | P 21 2 21 |
Unit cell lengths | 132.450, 152.180, 202.930 |
Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 50.550 | 3.610 |
High resolution limit [Å] | 3.500 | 3.500 |
Rmerge | 0.903 | |
Number of reflections | 52333 | 4425 |
<I/σ(I)> | 5.7 | 2 |
Completeness [%] | 99.8 | 98.6 |
Redundancy | 5.6 | |
CC(1/2) | 0.933 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, SITTING DROP | 5.5 | 293 | 32% PEG 400, 4% PEG 3350, 0.01 M cadmium chloride, 0.1 M sodium acetate pH 5.5 |