Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

6BAQ

Mus musculus BPIFA1

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsAPS BEAMLINE 23-ID-B
Synchrotron siteAPS
Beamline23-ID-B
Temperature [K]100
Detector technologyCCD
Collection date2014-10-18
DetectorMARMOSAIC 300 mm CCD
Wavelength(s)1.0332
Spacegroup nameC 1 2 1
Unit cell lengths132.200, 200.582, 89.499
Unit cell angles90.00, 126.15, 90.00
Refinement procedure
Resolution41.789 - 2.503
R-factor0.222884893344
Rwork0.221
R-free0.27824
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)4kgh
RMSD bond length0.008
RMSD bond angle1.146
Data scaling softwareHKL-2000
Phasing softwarePHASER
Refinement softwareCoot (1.12_2829)
Data quality characteristics
 Overall
Low resolution limit [Å]41.800
High resolution limit [Å]2.500
Rmerge0.071
Number of reflections64175
<I/σ(I)>24.8
Completeness [%]98.9
Redundancy6
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, HANGING DROP4.2310.1520% PEG 1000, 0.2 M Lithium Sulfate, 0.1 M Phosphate-citrate pH 4.2

223532

PDB entries from 2024-08-07