Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

6BAI

Multiconformer model of apo K197C PTP1B at 100 K

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsALS BEAMLINE 8.3.1
Synchrotron siteALS
Beamline8.3.1
Temperature [K]100
Detector technologyPIXEL
Collection date2016-12-21
DetectorDECTRIS PILATUS 6M
Wavelength(s)1.11583
Spacegroup nameP 31 2 1
Unit cell lengths87.265, 87.265, 104.103
Unit cell angles90.00, 90.00, 120.00
Refinement procedure
Resolution75.574 - 1.950
R-factor0.2079
Rwork0.206
R-free0.25690
Structure solution methodMOLECULAR REPLACEMENT
RMSD bond length0.015
RMSD bond angle1.302
Data reduction softwareXDS (Jun 1, 2017)
Data scaling softwareXDS (Jun 1, 2017)
Phasing softwarePHASER
Refinement softwarePHENIX
Data quality characteristics
 OverallInner shellOuter shell
Low resolution limit [Å]75.57475.5742.000
High resolution limit [Å]1.9508.7201.950
Rmerge0.0750.0223.027
Rmeas0.0770.0233.107
Total number of observations651902
Number of reflections333124362419
<I/σ(I)>2491.741.01
Completeness [%]98.199.898.1
Redundancy19.5716.68319.509
CC(1/2)1.0001.0000.416
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION7.5277well solution: 0.3 M magnesium acetate, 0.1 M HEPES pH 7.5, 0.1% beta-mercaptoethanol, 10-26% PEG 8000, 2% ethanol

222624

PDB entries from 2024-07-17

PDB statisticsPDBj update infoContact PDBjnumon