6XPZ
Human antibody S1V2-83 in complex with the influenza hemagglutinin head domain of A/Moscow/10/1999(H3N2)
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | APS BEAMLINE 24-ID-C |
Synchrotron site | APS |
Beamline | 24-ID-C |
Temperature [K] | 80 |
Detector technology | PIXEL |
Collection date | 2018-10-23 |
Detector | DECTRIS PILATUS 6M-F |
Wavelength(s) | 0.97910 |
Spacegroup name | P 21 2 21 |
Unit cell lengths | 85.790, 103.710, 220.000 |
Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 49.100 | 3.573 |
High resolution limit [Å] | 3.450 | 3.450 |
Rmerge | 0.212 | 1.149 |
Rmeas | 0.225 | 1.216 |
Rpim | 0.073 | 0.395 |
Number of reflections | 26508 | 2582 |
<I/σ(I)> | 10.01 | 2.06 |
Completeness [%] | 99.5 | 99.08 |
Redundancy | 9 | 9.2 |
CC(1/2) | 0.996 | 0.837 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, HANGING DROP | 291.15 | 5% w/v PEG4000 |