6XCP
Immune receptor complex
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | AUSTRALIAN SYNCHROTRON BEAMLINE MX2 |
Synchrotron site | Australian Synchrotron |
Beamline | MX2 |
Temperature [K] | 100 |
Detector technology | PIXEL |
Collection date | 2019-03-07 |
Detector | DECTRIS EIGER X 16M |
Wavelength(s) | 0.9537 |
Spacegroup name | P 21 21 21 |
Unit cell lengths | 65.977, 116.788, 124.187 |
Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
Resolution | 43.730 - 3.300 |
R-factor | 0.2359 |
Rwork | 0.234 |
R-free | 0.26830 |
Structure solution method | MOLECULAR REPLACEMENT |
Starting model (for MR) | 4z7u |
RMSD bond length | 0.002 |
RMSD bond angle | 0.500 |
Data reduction software | XDS |
Data scaling software | Aimless |
Phasing software | PHASER |
Refinement software | PHENIX (1.15_3459) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 43.730 | 3.418 |
High resolution limit [Å] | 3.300 | 3.300 |
Rmerge | 0.069 | 0.418 |
Rmeas | 0.097 | 0.592 |
Rpim | 0.069 | 0.418 |
Number of reflections | 15005 | 1466 |
<I/σ(I)> | 8.46 | 1.58 |
Completeness [%] | 99.9 | 100 |
Redundancy | 2 | |
CC(1/2) | 0.994 | 0.994 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, HANGING DROP | 293.15 | 13% PEG 8000, 0.2M Potassium dihydrogen phosphate |